Pyrolysis plastic to fuel oil recycling plant product introduction
The main part of the pyrolysis plant is the condenser and reactor. The reactor is made by the steel quality Q245R, Condenser is used to cool the oil gas waste plastic generated. Inside the condenser there are cooling pipe. Then there are safety device, dedusting system, sealing device.
First put the raw material into the reactor, close the reactor with the fuel natural gas or coal. Temperature reached about 180 Celsius degrees, waste plastic will begin crack, and oil gas will come out.
The oil will go into the condenser. The oil gas will become liquid oil. Some oil gas which cannot be condensed will be recycled to the reactor to heat the reactor through a pipe which is contact with the reactor. The energy is only used in the start of the pyrolysis plant, once the plant is running the plant will used its own gas to heat the reactor. After pyrolysis the gas will come out the reactor, the temperature falls down we can discharge the carbon black.
The temperature deduced to 50 degree Celsius. Worker can open the reactor door.
Then we can start next batch.
During the process of the plastic to oil there will be no pollution to the environment no waste gas, waste water, solid waste and so on. The process is very safe with the vacuum system and well sealing reactor.
Technical parameter of pyrolysis plastic to fuel oil recycling plant | ||||
---|---|---|---|---|
Items | Contents | |||
1 | Equipment type | DY-1-6 | DY-1-8 | DY-1-10 |
2 | Raw material | waste plastic, waste tyre, waste rubber, | ||
3 | Structural form | Horizontal rotation | Horizontal rotation | Horizontal rotation |
4 | 24-hour Capacity | 6 ton | 8 ton | 10 ton |
5 | Oil yield | 2.7-3.3ton | 3.6 -4.4ton | 4.5 -5.5ton |
6 | Operating pressure | Normal | Normal | Normal |
7 | Material of pyrolysis Reactor | Q245R | Q245R | Q245R |
8 | Thickness of pyrolysis Reactor | 16mm | 16mm | 16mm |
9 | Rotate speed of pyrolysis Reactor | 0.4turn/minute | 0.4turn/minute | 0.4turn/minute |
10 | Total power | 19KW | 19KW | 19KW |
11 | Mode of cooling | Water cooling | Water cooling | Water cooling |
12 | Cooling area of condenser | 100sqm | 100sqm | 100sqm |
13 | Kind of transmission | Internal gear drive | Internal gear drive | Internal gear drive |
14 | Noise dB(A) | ≤85 | ≤85 | ≤85 |
15 | Size of Reactor(D×L) | 2200×6000 | 2200×6600 | 2600×6600 |
16 | Working form | Intermittent operation | Intermittent operation | Intermittent operation |
17 | Delivery time | 20days | 20days | 20days |
18 | Weight | 27T | 30T | 35T |